Global Global Algérie Français Algeria English Angola Português Angola English Argentina Español Argentina English Australia English Austria Deutsch Austria English Azerbaijan English Azerbaijan Русский Bahrain English Bangladesh English Belgium English Belgium Français Belgium Nederlands Brazil Português Brazil English Bulgaria български Bulgaria English Cameroon English Cameroon Français Canada English Canada Français Chile Español Chile English China 中文 China 日本語 China English Colombia Español Colombia English Croatia English Czech Republic Čeština Czech Republic English Denmark English Djibouti English Ecuador Español Ecuador English Egypt English Estonia English Ethiopia English Finland Suomi Finland English France Français France English Georgia English Georgia Русский Germany Deutsch Germany English Ghana English Greece Ελληνικά Greece English Guatemala Español Guatemala English Hong Kong, China English Hong Kong, China 中文 Hungary Magyar Hungary English India English Indonesia English Iraq English Ireland English Italy Italiano Italy English Ivory Coast Français Ivory Coast English Japan 日本語 Japan English Jordan English Kazakhstan Русский Kazakhstan English Kenya English Kuwait English Kyrgyzstan Русский Kyrgyzstan English Latvia English Lithuania English Malaysia English Mauritius English Mauritius français (Maurice) Mexico Español Mexico English Moldova Română Moldova English Mongolia English Morocco English Morocco Français Mozambique Português Mozambique English Netherlands Nederlands Netherlands English New Zealand English Nigeria English Norway English Oman English Pakistan English Paraguay Español Paraguay English Peru Español Peru English Philippines English Poland Polski Poland English Portugal Português Portugal English Qatar English Republic of Korea 한국어 Republic of Korea English Romania Română Romania English Saudi Arabia English Serbia Српски Serbia English Singapore English Slovakia English Slovenia English South Africa English Spain English Spain Español Sri Lanka English Sweden English Switzerland Deutsch Switzerland Français Switzerland Italiano Switzerland English Tanzania English Thailand ไทย Thailand English Togo English Togo Français Tunisia English Tunisia Français Türkiye Türkçe Türkiye English Turkmenistan Русский Turkmenistan English Ukraine Українська Ukraine English United Arab Emirates English United Kingdom English Uruguay Español Uruguay English USA English Uzbekistan English Uzbekistan Русский Vietnam Tiếng Việt Vietnam English

Flame Retardant Rating Assessment for Heat Shrink Films: Standards, Methods, and Classifications

Flame retardant rating assessment is a critical verification process for heat shrink films and tubing used in electrical insulation, electronics protection, and industrial packaging. This guide explains the major flammability standards—including UL 94, IEC 60695, ISO 4589, and GB/T 2408—covering sample preparation, test procedures, classification criteria, and practical selection guidance for manufacturers seeking regulatory compliance.

Technical Overview

Heat shrink films are thermoplastic or cross-linked polymer materials—commonly polyolefin, PVC, PET, or fluoropolymers—that contract tightly around an object when exposed to heat, typically between 80 °C and 200 °C. Because these materials are frequently applied to energized electrical connections, cable harnesses, battery modules, and electronic assemblies, their fire performance is a primary safety concern. A flame retardant rating assessment determines whether a specific heat shrink film will self-extinguish, burn slowly, or propagate flame when exposed to an ignition source.

Flame retardancy in heat shrink films is achieved through halogenated systems (brominated or chlorinated compounds combined with antimony trioxide synergists) or halogen-free systems (metal hydroxides such as aluminum trihydrate and magnesium hydroxide, phosphorus-based agents, and intumescent formulations). Regulatory pressures such as RoHS and REACH have accelerated the shift toward halogen-free solutions, particularly in consumer electronics and electric vehicle applications.

Rating assessment is typically conducted by accredited third-party laboratories against internationally recognized flammability standards. The resulting classification—such as UL 94 V-0, VTM-0, or HB—directly determines whether a material is acceptable for a given end-use application under product safety standards including IEC 62368-1, UL 224 for extruded insulating tubing, and UL 746 for polymeric materials.

Testing Samples

Polyolefin Heat Shrink Film

Radiation cross-linked polyethylene (PE) and polyolefin blends are the most widely used base materials. Specimens must be supplied in both the expanded (as-supplied) state and, where required by the specification, in the fully recovered (shrunk) state, since cross-linking and recovery can alter burning behavior.

PVC and PET Shrink Film

PVC films contain chlorine in the polymer backbone and often achieve higher Limiting Oxygen Index values naturally, while PET films generally require additive packages to reach flame retardant classifications. Both are tested at minimum and maximum nominal thickness.

Fluoropolymer and Specialty Films

PTFE, FEP, and PVA-based films used in high-temperature or harsh environments are assessed using the same vertical and horizontal burning protocols, with additional consideration for their higher melting points.

Specimen Preparation and Conditioning

For vertical and horizontal burning tests, specimens are cut to 125 mm × 13 mm strips at the as-manufactured thickness. Because a flammability rating is only valid at the thickness tested, assessment programs normally include both the thinnest and thickest commercial variants. Specimens are conditioned at 23 °C ± 2 °C and 50 % ± 5 % relative humidity for a minimum of 48 hours in accordance with ISO 291 prior to testing. For thin films that distort, curl, or shrink away from a burner flame, specimens are rolled longitudinally around a mandrel into a cylindrical form and evaluated under the VTM (Vertical Thin Material) protocol instead.

Testing Items

A comprehensive flame retardant assessment for heat shrink film typically includes the following evaluation items:

  • Vertical burning classification: UL 94 V-0, V-1, and V-2
  • Thin material vertical burning classification: UL 94 VTM-0, VTM-1, and VTM-2
  • Horizontal burning classification: UL 94 HB, HB 40 (IEC 60695-11-10)
  • Advanced vertical classification at 500 W: UL 94 5VA and 5VB
  • Limiting Oxygen Index (LOI) determination
  • Glow wire flammability index (GWFI) per IEC 60695-2-12
  • Glow wire ignition temperature (GWIT) per IEC 60695-2-13
  • Needle flame test per IEC 60695-11-5
  • Flaming drip evaluation using surgical cotton indicators
  • Smoke density and toxic gas emission screening where required by end-use specifications

Testing Methods

UL 94 Vertical Burning Test (V-0 / V-1 / V-2)

Five conditioned specimens are mounted vertically and exposed twice to a 20 mm (50 W) methane burner flame for 10 seconds each, with the second application occurring after the specimen self-extinguishes from the first. Classifications are assigned based on individual afterflame times, total afterflame time across the specimen set, afterglow duration, whether flame reaches the clamp, and whether flaming drips ignite cotton placed beneath the specimen. To achieve V-0, each afterflame time must not exceed 10 seconds, the total afterflame time for the set must not exceed 50 seconds, and no flaming drips may ignite the cotton. V-1 allows afterflame times up to 30 seconds and a 250-second total, while V-2 shares the timing criteria of V-1 but permits flaming drips that ignite the cotton.

UL 94 VTM Thin Material Test

Because heat shrink films are frequently thinner than the minimum thickness for standard V-series testing, specimens are rolled into a cylinder, secured to the mounting rod, and tested using a procedure analogous to the vertical burning test. VTM-0, VTM-1, and VTM-2 correspond to the burning-time and dripping criteria of V-0, V-1, and V-2 respectively, and this classification is the most commonly specified rating for thin gauge heat shrink films.

Horizontal Burning Test (HB / HB 40 / HB 75)

Specimens are clamped horizontally at a 45-degree tilt of the marked edge and ignited at one end with a 25 mm flame applied for 30 seconds. The burning rate between the 25 mm and 100 mm gauge marks is measured. Materials classified HB 40 burn no faster than 40 mm/min, and HB 75 no faster than 75 mm/min, or the flame must extinguish before the 100 mm mark. Horizontal ratings represent the lowest flame retardancy tier and are generally insufficient for energized electrical applications.

Limiting Oxygen Index (ISO 4589-2 / ASTM D2863 / GB/T 2406.2)

The LOI test determines the minimum oxygen concentration, in a nitrogen-oxygen mixture, required to sustain candle-like burning of a vertically mounted specimen. Since ambient air contains approximately 21 % oxygen, a film with an LOI of 27 or higher is commonly regarded as flame retardant in industry practice, and values above 32 indicate strongly self-extinguishing behavior. LOI provides a quantitative, repeatable metric that complements pass/fail classifications.

Glow Wire Tests (IEC 60695-2 Series)

A glow wire heated to a specified temperature (typically 550 °C, 650 °C, 750 °C, 850 °C, or 960 °C) is pressed against the specimen for 30 seconds. GWFI evaluates whether the specimen ignites or produces flaming droplets that ignite tissue paper, while GWIT establishes the temperature 25 K above the point at which ignition no longer occurs. These tests are essential for heat shrink films used in unattended electrical equipment and household appliances.

Automotive and Railway Screening

For interior automotive applications, horizontal burning rate is measured per ISO 3795 or FMVSS 302, while heat shrink materials used in rolling stock may additionally require smoke density testing per ISO 5659-2 and fire performance evaluation under EN 45545-2 hazard level requirements.

Applications

Flame retardant rated heat shrink films serve critical protective functions across multiple industries, where verified flammability classifications are a precondition for design approval:

  • Electrical insulation of wire splices, solder joints, and terminal connections in appliances and power distribution assemblies
  • Cable harness bundling and identification in automotive wiring systems requiring low flame propagation
  • Electric vehicle battery module wrapping, cell wrapping, and busbar insulation where VTM-0 or V-0 performance with halogen-free chemistry is typically mandated
  • Consumer electronics protection and component encapsulation under IEC 62368-1 material flammability requirements
  • Aerospace and rail transit installations governed by stringent smoke and toxicity criteria
  • Industrial packaging of electronic components and flammable-sensitive goods during storage and shipment
  • Medical device manufacturing, where self-extinguishing materials reduce fire risk around powered equipment

FAQ

What does a UL 94 V-0 rating mean for heat shrink film?

A V-0 rating means the film self-extinguishes within 10 seconds of each flame application, the total afterflame time for a five-specimen set does not exceed 50 seconds, and no flaming drips ignite cotton. It is the most widely specified vertical burning classification for electrical insulation materials.

When is a VTM rating used instead of a standard V rating?

VTM classifications are applied to thin materials—typically films below the thickness range of the standard vertical test—that distort, shrink, or retract when exposed to the burner flame. Specimens are rolled into cylinders for testing, and VTM-0 represents the highest thin-film performance tier.

Is a high LOI value sufficient to prove flame retardancy?

No. LOI is a useful quantitative screening indicator, but most product safety standards and customers require a pass/fail classification such as UL 94 V-0 or VTM-0, and in many cases glow wire data, issued through formal assessment by accredited third-party laboratories.

How long does a complete assessment take?

Standard sample conditioning plus a single burning test series is usually completed within five to ten working days. Full programs covering multiple thicknesses, both pre- and post-recovery states, and glow wire or smoke testing may require two to four weeks.

Are halogen-free flame retardant heat shrink films available at V-0 level?

Yes. Modern halogen-free polyolefin formulations using metal hydroxide and phosphorus-based synergists achieve V-0 and VTM-0 classifications while meeting RoHS and REACH requirements, and they are increasingly preferred in automotive, consumer, and medical electronics applications where low smoke and halogen-free emissions are specified.